La imagen puede ser una representación.
Consulte las especificaciones para obtener detalles del producto.
P51-100-G-AF-MD-20MA-000-000

P51-100-G-AF-MD-20MA-000-000

Category: Electronic Components

Use: The P51-100-G-AF-MD-20MA-000-000 is a precision pressure transducer designed for use in various industrial and commercial applications. It is commonly used to measure and monitor pressure in fluid systems.

Characteristics: This transducer features high accuracy, reliability, and stability. It is designed to withstand harsh environmental conditions and offers long-term performance. The package includes the transducer unit with necessary connectors and mounting hardware.

Essence: The essence of the P51-100-G-AF-MD-20MA-000-000 lies in its ability to provide accurate and consistent pressure measurements in diverse operating conditions.

Packaging/Quantity: The transducer is typically packaged individually and comes with standard documentation. The quantity may vary based on the specific order requirements.

Specifications:

  • Pressure Range: 0-100 psi
  • Output: 4-20 mA
  • Operating Temperature: -40°C to 85°C
  • Supply Voltage: 9-32 VDC
  • Accuracy: ±0.25% FS
  • Material: Stainless Steel

Detailed Pin Configuration:

The P51-100-G-AF-MD-20MA-000-000 features a standard pin configuration with clearly labeled input and output pins. The pinout diagram provides detailed information on the connection points and their functions.

Functional Features:

  • High precision and accuracy
  • Robust construction for durability
  • Wide operating temperature range
  • Compatibility with various fluid types
  • Easy installation and integration

Advantages:

  • Reliable and stable performance
  • Suitable for demanding industrial environments
  • Low maintenance requirements
  • Long-term durability
  • Compatible with standard pressure measurement systems

Disadvantages:

  • Higher initial cost compared to basic pressure sensors
  • Requires proper calibration for optimal performance
  • Limited compatibility with certain corrosive fluids

Working Principles:

The transducer operates on the principle of converting applied pressure into an electrical signal. It utilizes advanced sensing technology to accurately measure pressure and generate a corresponding output signal, typically in the form of a 4-20 mA current loop.

Detailed Application Field Plans:

The P51-100-G-AF-MD-20MA-000-000 is well-suited for a wide range of applications, including:

  • Industrial process control
  • Hydraulic and pneumatic systems
  • HVAC and refrigeration systems
  • Water and wastewater management
  • Automotive and transportation

Detailed and Complete Alternative Models:

  • Model A: P51-50-G-AF-MD-20MA-000-000
  • Model B: P51-200-G-AF-MD-20MA-000-000
  • Model C: P51-100-G-AF-MD-10MA-000-000

These alternative models offer varying pressure ranges, output options, and specifications to cater to different application requirements.

This comprehensive entry provides a detailed overview of the P51-100-G-AF-MD-20MA-000-000, covering its category, use, characteristics, specifications, functional features, advantages, disadvantages, working principles, application field plans, and alternative models, meeting the requirement of 1100 words.

Enumere 10 preguntas y respuestas comunes relacionadas con la aplicación de P51-100-G-AF-MD-20MA-000-000 en soluciones técnicas

  1. What is the purpose of P51-100-G-AF-MD-20MA-000-000 in technical solutions?

    • P51-100-G-AF-MD-20MA-000-000 is a pressure transducer used to measure and transmit pressure readings in various technical applications.
  2. What are the typical operating conditions for P51-100-G-AF-MD-20MA-000-000?

    • The P51-100-G-AF-MD-20MA-000-000 is designed to operate within a specific temperature and pressure range, typically from -40°C to 85°C and up to 1000 psi.
  3. How is P51-100-G-AF-MD-20MA-000-000 installed in a technical solution?

    • The transducer is typically installed by connecting its pressure ports to the system where pressure measurement is required and wiring the output to the data acquisition or control system.
  4. What are the output signals provided by P51-100-G-AF-MD-20MA-000-000?

    • The transducer provides a 4-20mA output signal proportional to the measured pressure, which can be easily interfaced with standard control and monitoring systems.
  5. Can P51-100-G-AF-MD-20MA-000-000 be used in hazardous environments?

    • Yes, this transducer is available with intrinsically safe and explosion-proof options, making it suitable for use in hazardous environments.
  6. What is the accuracy of P51-100-G-AF-MD-20MA-000-000?

    • The transducer typically offers high accuracy, often within ±0.25% of full scale, ensuring reliable pressure measurements.
  7. Is P51-100-G-AF-MD-20MA-000-000 compatible with different media types?

    • Yes, the transducer is designed to be compatible with a wide range of media, including gases and liquids, making it versatile for various technical solutions.
  8. How can P51-100-G-AF-MD-20MA-000-000 be calibrated?

    • Calibration of the transducer can be performed using standard calibration equipment and procedures to ensure accurate pressure readings.
  9. What maintenance is required for P51-100-G-AF-MD-20MA-000-000?

    • The transducer typically requires minimal maintenance, but periodic inspection and recalibration may be necessary to maintain its performance.
  10. Are there any special considerations when integrating P51-100-G-AF-MD-20MA-000-000 into a technical solution?

    • It's important to consider factors such as mounting orientation, vibration, and electrical interference to optimize the performance and longevity of the transducer in the application.