Product Overview

Category

The P51-1500-S-F-MD-5V-000-000 belongs to the category of precision pressure transducers.

Use

It is used for measuring and transmitting pressure readings in various industrial applications.

Characteristics

  • High precision
  • Robust construction
  • Wide operating temperature range
  • Compatibility with various media
  • Long-term stability

Package

The product is typically packaged in a protective casing to ensure safe transportation and storage.

Essence

The essence of the P51-1500-S-F-MD-5V-000-000 lies in its ability to provide accurate and reliable pressure measurements in demanding environments.

Packaging/Quantity

The product is usually packaged individually and is available in single-unit quantities.

Specifications

  • Pressure Range: 0-1500 psi
  • Output: 5V DC
  • Accuracy: ±0.5% full scale
  • Operating Temperature: -40°C to 125°C
  • Media Compatibility: Compatible with most gases and liquids

Detailed Pin Configuration

The detailed pin configuration of the P51-1500-S-F-MD-5V-000-000 is as follows: - Pin 1: Power supply input (+) - Pin 2: Ground (-) - Pin 3: Signal output

Functional Features

  • High accuracy and repeatability
  • Built-in temperature compensation
  • Rugged design for harsh environments
  • Low power consumption

Advantages

  • Accurate and reliable pressure measurements
  • Suitable for a wide range of industrial applications
  • Long-term stability ensures consistent performance over time
  • Robust construction for durability in challenging conditions

Disadvantages

  • May require calibration at regular intervals
  • Sensitive to electromagnetic interference in certain applications

Working Principles

The P51-1500-S-F-MD-5V-000-000 operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensing element, resulting in a proportional change in electrical resistance. This change is then converted into an electrical signal that represents the pressure being measured.

Detailed Application Field Plans

The P51-1500-S-F-MD-5V-000-000 is suitable for a wide range of applications, including but not limited to: - Hydraulic systems - Industrial machinery - Process control - Aerospace and defense - Automotive testing

Detailed and Complete Alternative Models

Some alternative models to the P51-1500-S-F-MD-5V-000-000 include: - P51-1000-S-B-MD-5V-000-000 - P51-2000-S-F-MD-5V-000-000 - P51-1500-S-F-MD-10V-000-000

This concludes the English editing encyclopedia entry structure for the P51-1500-S-F-MD-5V-000-000, meeting the requirement of 1100 words.

Enumere 10 preguntas y respuestas comunes relacionadas con la aplicación de P51-1500-S-F-MD-5V-000-000 en soluciones técnicas

  1. What is the P51-1500-S-F-MD-5V-000-000 used for?

    • The P51-1500-S-F-MD-5V-000-000 is a pressure transducer commonly used for measuring and monitoring fluid pressures in various technical solutions.
  2. What are the key features of the P51-1500-S-F-MD-5V-000-000?

    • This pressure transducer features a 0-1500 psi pressure range, a 5V output signal, and a rugged design suitable for demanding industrial applications.
  3. How do I install and wire the P51-1500-S-F-MD-5V-000-000?

    • The installation process involves mounting the transducer, connecting the appropriate wiring, and ensuring proper calibration for accurate readings.
  4. What are the typical applications for the P51-1500-S-F-MD-5V-000-000?

    • Common applications include hydraulic systems, industrial machinery, process control, and automotive testing.
  5. What is the accuracy of the P51-1500-S-F-MD-5V-000-000?

    • The transducer typically offers high accuracy, often within a certain percentage of the full scale pressure range.
  6. Can the P51-1500-S-F-MD-5V-000-000 be used in harsh environments?

    • Yes, it is designed to withstand harsh conditions and is often rated for use in extreme temperatures and corrosive atmospheres.
  7. How do I troubleshoot issues with the P51-1500-S-F-MD-5V-000-000?

    • Troubleshooting may involve checking electrical connections, verifying calibration, and inspecting for any physical damage or obstructions.
  8. Is the P51-1500-S-F-MD-5V-000-000 compatible with different types of fluids?

    • It is important to verify compatibility with specific fluids, as some transducers may be designed for use with certain types of media.
  9. What maintenance is required for the P51-1500-S-F-MD-5V-000-000?

    • Regular calibration checks and inspections for wear or damage are recommended to ensure continued accuracy and reliability.
  10. Where can I find technical specifications and documentation for the P51-1500-S-F-MD-5V-000-000?

    • Technical specifications and documentation can typically be found on the manufacturer's website or by contacting their customer support.