La imagen puede ser una representación.
Consulte las especificaciones para obtener detalles del producto.
P51-1500-S-I-I36-20MA-000-000

P51-1500-S-I-I36-20MA-000-000

Category: Electronic Component

Use: The P51-1500-S-I-I36-20MA-000-000 is a pressure sensor designed for industrial applications. It is used to measure and monitor pressure in various systems and equipment.

Characteristics: This sensor has high accuracy, reliability, and stability. It is designed to withstand harsh industrial environments and has a wide operating temperature range. The package is compact and durable, suitable for integration into different industrial setups. The essence of this sensor lies in its ability to provide precise pressure measurements in challenging conditions. It is available in various packaging/quantity options to cater to different industrial needs.

Specifications: - Pressure Range: 0-1500 psi - Output Signal: 4-20mA - Electrical Connection: Integral Cable - Operating Temperature: -40°C to 85°C - Pressure Type: Sealed Gauge - Material: Stainless Steel

Detailed Pin Configuration: The sensor has a 6-pin configuration: 1. Power Supply + 2. Power Supply - 3. Signal Output + 4. Signal Output - 5. Not Connected 6. Not Connected

Functional Features: - High precision pressure measurement - Robust construction for industrial use - Wide operating temperature range - 4-20mA output signal for easy integration with control systems

Advantages: - Accurate and reliable pressure measurement - Suitable for harsh industrial environments - Easy integration with existing control systems - Durable construction for long-term use

Disadvantages: - Limited pressure range compared to some other sensors - Requires proper calibration for optimal performance

Working Principles: The P51-1500-S-I-I36-20MA-000-000 operates on the principle of strain gauge technology. When pressure is applied, the strain gauges within the sensor deform, causing a change in electrical resistance. This change is then converted into a 4-20mA output signal proportional to the applied pressure.

Detailed Application Field Plans: This sensor is ideal for use in industrial hydraulic systems, pneumatic systems, pressure vessels, and process control applications. It can be integrated into manufacturing equipment, hydraulic presses, and industrial machinery to monitor and control pressure levels accurately.

Detailed and Complete Alternative Models: - P51-1000-S-I-I36-20MA-000-000 (0-1000 psi range) - P51-2000-S-I-I36-20MA-000-000 (0-2000 psi range) - P51-3000-S-I-I36-20MA-000-000 (0-3000 psi range)

This completes the entry for the P51-1500-S-I-I36-20MA-000-000 pressure sensor, covering its category, use, characteristics, specifications, pin configuration, functional features, advantages and disadvantages, working principles, application field plans, and alternative models.

Enumere 10 preguntas y respuestas comunes relacionadas con la aplicación de P51-1500-S-I-I36-20MA-000-000 en soluciones técnicas

  1. What is the P51-1500-S-I-I36-20MA-000-000 used for?

    • The P51-1500-S-I-I36-20MA-000-000 is a pressure transducer commonly used to measure and transmit pressure readings in various technical solutions.
  2. What is the operating range of the P51-1500-S-I-I36-20MA-000-000?

    • The operating range of the P51-1500-S-I-I36-20MA-000-000 is typically from 0 to 1500 psi.
  3. What type of output signal does the P51-1500-S-I-I36-20MA-000-000 provide?

    • The P51-1500-S-I-I36-20MA-000-000 provides a 4-20mA output signal, which is commonly used in industrial applications.
  4. Is the P51-1500-S-I-I36-20MA-000-000 suitable for use in harsh environments?

    • Yes, the P51-1500-S-I-I36-20MA-000-000 is designed to withstand harsh environmental conditions and is often used in rugged industrial settings.
  5. What are the typical applications for the P51-1500-S-I-I36-20MA-000-000?

    • Typical applications for the P51-1500-S-I-I36-20MA-000-000 include hydraulic systems, industrial machinery, and process control systems.
  6. Does the P51-1500-S-I-I36-20MA-000-000 require calibration?

    • Yes, the P51-1500-S-I-I36-20MA-000-000 should be calibrated periodically to ensure accurate pressure measurements.
  7. Can the P51-1500-S-I-I36-20MA-000-000 be integrated with PLC systems?

    • Yes, the P51-1500-S-I-I36-20MA-000-000 can be easily integrated with PLC (Programmable Logic Controller) systems for automated monitoring and control.
  8. What is the temperature range for the P51-1500-S-I-I36-20MA-000-000?

    • The P51-1500-S-I-I36-20MA-000-000 typically operates within a temperature range of -40°C to 85°C.
  9. Is the P51-1500-S-I-I36-20MA-000-000 compatible with corrosive media?

    • The P51-1500-S-I-I36-20MA-000-000 is available with various diaphragm materials to ensure compatibility with a wide range of media, including corrosive substances.
  10. What is the recommended installation procedure for the P51-1500-S-I-I36-20MA-000-000?

    • The P51-1500-S-I-I36-20MA-000-000 should be installed following the manufacturer's guidelines, ensuring proper sealing and protection from external elements.